Research
Neural
The study demonstrated the feasibility, safety, and usefulness of using a simple edge‐to‐edge, reusable oral appliance in drug-induced sleep endoscopy.
Oral appliances may be a viable option for patients undergoing sleep apnea evaluation.
StrongSupportsmedium confidence
We showed the feasibility, safety, and usefulness of using simple edge‐to‐edge, reusable OA in DISE.
Why this rating
Based on the study design involving polysomnography and drug-induced sleep endoscopy.
Source
Upper Airway Surgery or Weight Control? Modified Drug‐Induced Sleep Endoscopy for Obstructive Sleep Apnea
Hung‐Che Lin et al. · Otolaryngology · 2023
DOI 10.1002/ohn.364
cohort · n=83Cited 5×
Read the paper DOI resolved against Crossref · corpus check 2026-06-10
More from this paper
- Patients with persistent complete concentric velopharyngeal collapse in the supine position had a mean apnea–hypopnea index (AHI) of 54.7 events/h, significantly higher than the 60 patients without such collapse in position 4, who had a mean AHI of 35.5 events/h.Strong
- The degree of velum and tongue base obstruction was significantly associated with sleep apnea severity in positions 2, 3, and 4 after adjusting for age, BMI, tonsil size, and tongue position.Strong
Related findings · Neural
This is one finding among thousands. Every one is graded and traced to its source, so you can see what the evidence actually supports. Browse the research →